• fujitsu rx100 s2 manual

    fujitsu rx100 s2 manual

    Download Link: ➡ fujitsu rx100 s2 manual



    File Name: fujitsu rx100 s2 manual.pdf
    Size: 1232 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 14 May 2019, 12:21 PM
    Rating: 4.6/5 from 560 votes.


    Last checked: 3 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download fujitsu rx100 s2 manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    fujitsu rx100 s2 manual

    The server's power LED is lit green. When the power is turned on, the server Power On Self Test (POST). The server's power LED is lit amber. Power switch The server's power LED is lit amber Turn off the display and peripheral devices.Entry of water, a paper clip, or other liquids or metal objects can cause electric shock or failures. The CD-ROM tray comes out a little. CD-ROM eject button Pull the CD-ROM tray out. CD-ROM tray Place the CD-ROM at the center of the tray. Please read this chapter before starting installation. 2.1 Preparation on the Server.2.2 Selecting the Installation Method. You can turn the power on from a client (via a LAN) by utilizing the Wakeup on LAN (WOL) function.Before removing the hard disk unit, make sure that the disk has already been initialized by the RAID Management Tool or others. Windows PE for starting up ServerStart can be only used for installing Windows Server 2003 or Windows 2000 Server provided under a separate legal license. To check the RAID card configuration, start up WebBIOS.The Windows installer starts and the Setup window appears. When the uninstallation is executed successfully, Fujitsu ServerStart is deleted. Leave it and complete the operation. Depending on the hardware configuration, this process may take a few minutes. Creation of a ServerStart floppy disk starts.The guided mode for the selected OS starts up. Start up the wizards to set items in the following procedures. Exiting the wizard returns the display to the guided mode window. In the guided mode, the RAID wizard is displayed only when a RAID card is installed. When changing the RAID card, delete the physical pack beforehand.The disk wizard starts up with the default settings. Change them as necessary.ServerStart can configure multiple network patterns. The setting window differs depending on the OS to be installed. The following describes operations on Windows Server 2003. The OS installation wizard closes. The application wizard appears.

    • fujitsu rx100 s2 manual, fujitsu rx100 s2 manual pdf, fujitsu rx100 s2 manual download, fujitsu rx100 s2 manual review, fujitsu rx100 s2 manual user.

    Make sure to read this In addition, the workflow, from placing Be sure to perform It also covers Make sure to read this section. Chapter 1 Overview This chapter explains component names and basic operations of this server, as well as an overview of the software provided with this server. It is the customer's responsibility to maintain backup copies in advance. In case of data loss, Fujitsu assumes no liability for data maintenance or restoration and damages that occur as a result of the data loss for any reason, except for items covered under warranty. These are used to emphasize important points for your safety and that of others. The following are the symbols and their meanings: Ignoring this symbol could be potentially lethal. Please read it before using ServerStart.In addition, the workflow, from placing the server to starting the operation, is also described. 1.1 RX100 S2.1.2 Supplied Software. It offers easy server installation and proper installation of recommended drivers. To create a configuration file, use the ServerStart floppy disk supplied with this server. Store only one file on each floppy disk. This prevents possible mistakes in driver installation, such as installation of an older version or drivers which were not supplied with this server. System file configuration information, major registry settings, and event logs can be collected easily from the command line. The following high reliability tools are installed. When pressing this button, the front and rear system identification LEDs are lit blue so that the locations of devices being maintained can be determined. For 1000Mbps connection, a cable conforming to category 5 enhanced is required. As LAN connector A uses the Communication Streaming Architecture (CSA) port, its data transfer speed may be higher than that of LAN connector B. Refer to the manual included with the rack for procedures on opening other rack doors. Press the power switch on the front of the server.

    ServerStart starts up and a message appears prompting you to insert the ServerStart floppy disk.When Windows NT is used, or if the CD has not been copied 1. The display returns to the preconfiguration mode window. Eject the ServerStart floppy disk. Click the type of the driver you want to create. Click the driver disk you want to create. Prepare necessary drivers before installing Windows Server 2003. Some drivers are created from the ServerStart CD-ROM.The procedure differs depending on the connection of the installation hard disk. When installing the OS on a hard disk connected via the RAID card: Immediately, the following message appears at the bottom of the window.Prepare necessary drivers before installing Windows 2000 Server. Some drivers used with Windows 2000 Server are created from the ServerStart CD-ROM.The following message appears. When Service Pack 4 is applied 1. Insert the ServerStart CD-ROM into the drive of the server. When the ServerStart window appears, exit ServerStart. In addition to the case where the OS is installed manually, the driver must be installed when a LAN card is added. 4.3.1 Installing the LAN Driver (Windows Server 2003) The LAN driver installation procedure differs depending on whether the network adapter was recognized during the OS installation. The driver will be installed.If this option is specified, a new file is created each time the system unexpectedly stops.Specify the drive where the paging file is to be created.The value depends on the type of the set dump file.When the system unexpectedly stops, the process that records information to the log file is speeded up. According to the amount of memory installed in the server, available area of 50 to 800MB is required for the paging file in the boot volume. If the system file, system configuration or environment setting change at startup, etc., are damaged, such data can be reconstructed using the recovery information stored in the created system recovery disk.

    When Windows NT is used, or if the CD has not been copied 1. A message prompting you to insert the floppy disk appears. Set the ServerStart floppy disk in the write-enabled state. Creation of a ServerStart floppy disk starts. During installation, do not use the mouse or keyboard unless it is necessary for installation operations. Otherwise, installation may fail. Turn on the server and insert the ServerStart CD-ROM immediately. This message does not appear when Service Pack is not selected. Use the guided mode for normal installation. 3.3.1 Starting Up the Expert Mode Start up the expert mode. The expert mode starts. Start up the configuration tools to set items in the following procedures. Exiting a tool returns to the display to the expert mode window. Disk Manager starts up. Format the OS installation partition.ServerStart can configure multiple network patterns. The following describes operations on Windows Server 2003. When the installation partition is not empty, a confirmation message appears. This message does not appear when Service Pack is not selected. The system restarts. When the system restarts, log on to the server using the Administrator account for the local computer. This method is used when the target server does not have a CD-ROM or floppy disk drive. The DHCP service is installed. Create and configure a DHCP scope so that the IP address can be distributed. The preparation of the PXE server has been completed.Installation starts. All disk contents on the target server are deleted. Turn on the target server. It is started up via the network (PXE) and installation starts. Depending on the hardware configuration, this process may take a few minutes.By editing the configuration file created for installation on the first server, you can use it for installation on other servers of the same model and configuration. Turn on the server and insert the ServerStart CD-ROM immediately.

    Slot cover Expansion card The slot cover for PCI slot 2 is composed of a LowProfile slot cover and an Extension slot cover. Insert a card into slot 2 first, then insert another into slot 1. Also unplug all power cables from the server.Loosen the screws of the dummy unit, and remove the dummy unit. Screw Connect the IDE and power cables. Use the IDE and power cables connected to the server. Fix the connected cables between the pieces of the foam. They can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity. As the SCSI-ID is not set automatically, you must set it up in advance by referring to the followings. Loosen the screws (1) and slid the bay toward you to remove it (2). Hard disk bay Install the internal hard disk unit to the hard disk bay. Fasten the bay to the internal hard disk unit using the screws supplied with the disk unit. Insert the hard disk bay with the internal hard disk unit into the server (1), and tighten the screws (2). Connect SCSI and power cables. Connect the SCSI cable to the SCSI connector of the internal hard disk unit. Also, connect the power cable to the extension cable connector. Connection conditions vary depending on examples. See each example. Only a single backup cabinet can be connected to the server. Backup cabinet SCSI Ctrl U160 lp (PRIMERGY SX10:. Remove the card locking frame. PhoenixBIOS Setup Utility Main Advanced Security. Sets the type and operating mode for the connected internal hard disk unit.Sets system startup options.PhoenixBIOS Setup Utility Main Advanced Security Server Exit Item Specific Help Setup Warning Setting items on this menu to incorrect values may cause your system to malfunction. Configures the PCI devices. PhoenixBIOS Setup Utility Advanced PCI Configuration Item Specific Help Ethernet on Board PCI IRQ Configuration PCI SLOTS Configuration Info Change Values Select Item. The submenu configures additional settings.

    Eject the floppy disk according to the message and put a label on it.By storing this information, the system can be recovered with the stored information in case of a system failure (such as when the information is deleted due to the drain of the built-in battery). Maintenance tools are created with the FloppyBuilder function of ServerStart.When Windows NT is used, or if the CD has not been copied Insert the ServerStart CD-ROM into the client computer's CD-ROM drive. Eject the ServerStart floppy disk. Insert the prepared floppy disk by following the message. Perform the subsequent operations according to the messages on the window. Prepare floppy disks as many as the tools you want to create beforehand. Types of a Hardware Configuration Tool vary by model. Only a link down error between a LAN card (onboard LAN) and the switch it connects with, and the equivalent errors lead to switching of the route. The procedure differs depending on the OS being used. For Windows 2000 Server 1. Expansion cards Internal CD-ROM drive unit Memory modules Internal hard disk units When installing or removing devices, make sure to use the removed screws on the same location and devices that were last installed or removed. They can be damaged by static electricity. Also unplug all power cables from the server.Pull the server out toward you until it clicks so that it locks in place on the rails on both sides.Also unplug all power cables from the server. A memory of this server contains a single Dual In-Line Memory Module (DIMM) and you can add a single memory module at a time. This function disconnects the memory (one DIMM) judged to be defective (abnormal) during Power On Self Test (POST) to start the server. When POST is executed, if the memory capacity is discovered to be smaller than the capacity of the memory installed, there is a possibility of memory defect. Unplug the cable from the SCSI or RAID card installed in Slot 1.

    This release greatly supports the strategic objective of eLCM to consolidate and enhance management functions directly available (“embedded”) within the server for simplified, highly integrated and automated management processes. All rights reserved. Delivery subject to availability; right of technical modifications reserved. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries. Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured.

    Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Operating Manual RX100 S7 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. Thanks to its highly developed hardware and software components, the PRIMERGY RX100 S7 server offers a high level of data security and availability. Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation. Additional security is provided by the lockable rack door. The server occupies 1 height unit in the rack. For an overview of the different features please refer to table 1 on page 24. RX100 S7 Operating Manual 11 Introduction 1.

    If the boot sector is changed without a clear reason, it is necessary to scan the system for computer viruses with a virus detection program. Configures the Baseboard Management Controller (BMC). PhoenixBIOS Setup Utility Server IPMI Item Specific Help IPMI Specification Version BMC Firmware n.nn.nnnnnnnn Clear System Event Log. This submenu sets whether or not to allow the use of the installed memory. PhoenixBIOS Setup Utility Server Memory Status Item Specific Help. This submenu configures detailed settings for console redirection.Dust deposits may cause a server failure, fire, or electric shock. Flip the mouse over to remove the ball. Afterwards, wash it with water. Clean the inside of the mouse. Wipe the inside of the mouse, the roller, and the bottom cover with a damp cloth. Roller Insert the ball and apply the cover. For each situation, refer to the following.Check to see whether the power cable of the display is properly connected to the outlet.The write protection of the floppy disk may be applied.If the AC Lost log is stored simultaneously as shown below, this will not affect server operation. You can continue to use the server without taking any action. Check to see that the jumper pin detected - Warranty restricted.If the message still appears, the baseboard must be replaced.CPU is no longer available for The CPU is abnormal.Perform the corresponding resolution listed in the table.This message may be displayed when no disk array is configured and ServerStart is started during 256MB memory OS installation on the hard disk connected to the RAID card. If the server has 256MB memory and install the OS on the hard disk connected to the RAID card, make sure to configure a disk array using WebBIOS before starting ServerStart. Device names are displayed properly when all LAN drivers are installed and the system is restarted. Check and perform the corrective action against the relevant event.

    When the area for writing to the system event log is full, the server is set to automatically overwrite older event logs. The system will boot from the floppy disk and the DOS prompt is displayed.The menu window of Server Management Tools appears.FUJITSU SIEMENS USER MANAGEMENT COMPUTERS ID --- USER NAME --- 2 Operator 3 Administrator 4 OEM 5 Remote 6 admin. Additional security functions, which prevent unauthorized use, provided by the BIOS Setup Utility are also available to help maintain a highly reliable data security system. When a password is set, the server is accessible only to the users who know the password. The password is set in the BIOS Setup Utility.To remove this dust, head cleaning must be implemented. Such functions will rewind the tape after a backup is completed and then eject the media from the drive.Install or connect them after OS installation. Customers using the Linux distribution OS are advised to refer to the Fujitsu PRIMERGY website ( ).Add an optional CPU or change the Hyper-Threading setting in the BIOS Setup Utility. It also covers how to recycle the products. A Server Specifications.260 B Specifications for Internal Options. When you have bought an internal option as a standard option, check the contents of the optional package before use.It must be used to prevent electric shock. Use the following guidelines if it is necessary to replace the original cord set. Carefully prepare the end of the supply cord and fit a suitable plug. The menu closes. Switching between Functions This section explains how to switching between functions. This server must be disposed of as industrial waste. Supporting the New PRIMERGY M4 and PRIMEQUEST Servers launched, iRMC S5 comes with a new interactive UI and conforms to Redfish providing support for unified API.

    1 Concept and target groups for this manual This operating manual describes how to install, set up and operate your server. This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY RX100 S7 into operation. If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server ). The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option. E describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. I indicates additional information, notes and tips. 14 Operating Manual RX100 S7 2 Functional overview This section provides information on the features and technical data of the PRIMERGY RX100 S7 server. Customer Self Service (CSS) The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios. CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises. You can also fit your server with a ServerView Local Service Panel, which enables you to identify the type of component affected by the error directly on the server. In addition, CSS errors are displayed in the ServerView Operations Manager, the server management software from Fujitsu.

    Trusted Platform Module (TPM) A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). To do this, follow the third party manufacturer's instructions. This allows HDD modules to be plugged in or pulled out easily. If the server has a corresponding RAID configuration, defective HDD modules can also be replaced during operation. Hybrid configurations of SAS and SATA HDD modules within one drive cage are not supported. Onboard SATA controller A SATA controller is integrated on the system board; up to four SATA hard disk drives can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10. As an option, a battery backup unit (BBU) or a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of 512 Mbyte or 1 Gbyte is available. Power supply In its basic configuration the server has a standard power supply unit or a hotplug power supply unit that adjusts automatically to any mains voltage in the range 100 V - 240 V. Besides the hot-plug power supply unit, a second hot-plug power supply unit can be installed optionally to serve as a redundant power supply. If one power supply unit fails, the second power supply unit in the redundant configuration ensures operation can continue uninterrupted. High level of availability and data security When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method. The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes and monitors all components that are critical for system reliability. A RAID controller supports different RAID levels and increase the availability and data security of the system.

    The hot-plug HDD modules provide additional availability. RX100 S7 Operating Manual 19 Functional overview iRMC S3 with integrated management LAN connector The iRMC S3 (integrated Remote Management Controller) is a Baseboard Management Controller (BMC) with integrated management LAN connector and expanded functionality that was previously only available with additional plug-in cards. Major functions supported by the iRMC S3 include the following. Browser access via iRMC S3-s own Web server. Secure communication (SSH, SSL). Power Management for the managed server (depending on its system status). Power Consumption Management. Connecting virtual drives as remote storage. Text-based and graphic console bypass (Advanced Video Redirection). Remote Storage ? Command Line Interface (CLI). Simple, interactive or script-based iRMC S3 configuration. Customer Self Service (CSS).Multi-computer, global iRMC S3 user administration using an LDAP Directory Service. Power supply of the iRMC S3 via the system standby supply. Full-coverage alarm management. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken. The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console. The ServerView Operations Manager supports the following functions. Round-the-clock monitoring, regardless of server status. Remote storage via USB. Remote power on ? Temperature monitoring of the CPU and the surrounding area. Detailed status and error reports for processors and main memory. Power monitoring ? End-of-life monitoring of fans with prompt notification before failure. RX100 S7 Operating Manual 21 Functional overview ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. Service and support PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance.

    The handles and locks (touch points) used to exchange components are colored green to ensure simple and immediate recognition. In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green. PRIMERGY diagnostic LEDs fitted on the system board indicate which component (memory module, processor, fan or expansion card) is not functioning properly. The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update. With the iRMC S3 (integrated Remote Management Controller) on the system board, the PRIMERGY RX100 S7 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail. 22 Operating Manual RX100 S7 Functional overview ServerView Remote Management ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors. Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution. You can also start the text-based or graphic console bypass (Advanced Video Redirection, AVR) and connect virtual drives as remote storage. RX100 S7 Operating Manual 23 Functional overview 2.2 Server specification This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned. Europe Safety EN 60950-1 2ed. E Transport the server to the place where you want to set it up.

    E Components that have been ordered additionally may be delivered loose with the server. Install these in the server as described in the supplied documentation. E Configure the server and install the desired operating system and applications. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. V CAUTION! ? The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software. ? Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. V CAUTION! Hazardous moving parts. Keep away from moving fan blades. Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the server if this requirement is not met. ? Only transport the server in the original packaging or in packaging that protects it from impacts and jolts. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. ? Always connect the server and the attached peripherals to the same power circuit. When connecting the server, refer to the relevant instructions in this manual. ? Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). ? Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit). ? In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team. If you install other expansions, they may damage the system or violate the safety regulations.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :