• fujitsu primergy tx120 s3p manual

    fujitsu primergy tx120 s3p manual

    Download Link: ➡ fujitsu primergy tx120 s3p manual



    File Name: fujitsu primergy tx120 s3p manual.pdf
    Size: 2660 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 13 May 2019, 23:48 PM
    Rating: 4.6/5 from 552 votes.


    Last checked: 10 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download fujitsu primergy tx120 s3p manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    fujitsu primergy tx120 s3p manual

    The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the PRIMERGY TX120 S3 Upgrade and Maintenance manual). Do not throw batteries into the trash can. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth.All documentation must be included if the equipment is passed on to a third party. Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. Protect the server from dust, humidity and heat. Make sure that the server is acclimatized for the time indicated in this table before putting it into operation. If the server is positioned vertically, the stabilizers must be attached. The stabilizers must be attached in the correct direction (see figure 4 on page 48).Operating Manual TX120 S3. Operating Manual TX120 S3. If the server is positioned horizontally, ensure that the rubber feet are pointing downward. Operating Manual TX120 S3. Operating Manual TX120 S3. The additional connectors available on your server depend on the expansion cards installed. For further information refer to the “PRIMERGY TX120 S3 Upgrade and Maintenance manual”. CAUTION! The server is automatically set to a mains voltage in the range 100V - 240V. You may only operate the server if its rated voltage range corresponds to the local mains voltage. The insulated connector cannot now be disconnected from the server accidentally.

    • fujitsu primergy tx120 s3p manual, fujitsu primergy tx120 s3 manual, fujitsu primergy tx120 s3p manual, fujitsu primergy tx120 s3p manual pdf, fujitsu primergy tx120 s3p manual download, fujitsu primergy tx120 s3p manuals, fujitsu primergy tx120 s3p manual free.

    Carefully read the manual before using this product.Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. Although described in this manual, some sections do not apply to the Japanese market.For the Japanese market please use the URL: Each HDD module can accommodate an SATA hard disk drive with a maximum height of 1 inch. The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes and monitors all components that are critical for system reliability. A RAID controller supports different RAID levels and increase the availability and data security of the system. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken. The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update. With the iRMC S3 (integrated Remote Management Controller) on the system board, the Produktname server can also be maintained and serviced remotely. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors. The specifications for this server are liable to be updated without any notice. Please be forewarned.This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. If the server has been moved from a cold environment, condensation may form both inside and on the outside of the machine. Ensure that the power sockets on the device and the grounded power outlets are freely accessible. To disconnect it completely from the mains power supply, unplug all network power plugs from the grounded power outlets.

    Please ask your local Fujitsu service center for more detailed information. 2.1.1 Customer Replaceable Units (CRU) Server management error messages and diagnostic indicators on the front panel and system board will report defective Upgrade and Repair Units as customer replaceable CSS components. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.Refer to table 2 on page 32 for an overview of steps taken into account for calculating the average task duration: Step. You will find a list of required tools at the beginning of each procedure.Before installing and starting up a device, please observe the safety instructions listed in the following section. This will help you to avoid making serious errors that could impair your health, damage the device and endanger the data base. Keep all manuals and the other documentation (such as the technical manual, documentation DVD) close to the device. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Devices inside the server remain hot after shutdown.To ensure reliable protection, you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted, non-conducting metal part of the system. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. Use the Fujitsu ServerView Suite management software to plan the upgrade or replacement of hardware components. ServerView Suite documentation is available online at Component LEDs LEDs A, B and C are visible from the outside on the server rear.

    You can loosen the cable tie by opening the small locking lever (2). Operating Manual TX120 S3. Never connect, or disconnect cables during a thunderstorm. Never pull on a cable when disconnecting it. Always take hold of the cable by the plug. As a result, even if the key is locked, the drive cover can be removed. CAUTION! Do not pull too hard to avoid damage to the locking mechanism. Operating Manual TX120 S3. The HDD cover is replaced and the server locked in the reverse order. Operating Manual TX120 S3. Operating Manual TX120 S3. The ID card contains various system information, such as the product name, serial number, order number, MAC addresses and DNS name (in the Japanese market, only the product name and the serial number). CAUTION! Risk of loss of data.Lights up orange when the server is switched OFF, but mains voltage is present (standby mode).Flashes green when LAN transfer takes place.You can configure the onboard SATA controller either before or during installation with the ServerView Installation Manager. Switch the server off and disconnect the power plugs from the properly grounded power outlets. Do not clean any interior parts yourself; leave this job to a service technician. Do not use any cleaning agents that contain abrasives or may corrode plastic. To prevent it being removed from its location, the server can be secured to a fixed object with a steel cable running through a clip on the back. Switch off the server immediately. Risk of damaging the server. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor. Carefully read the manual before using this product.Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. Use the Fujitsu Illustrated Spares Catalog to identify the required spare part and obtain technical data and order information.

    If a Linux OS is used and the hardware clock has been configured as UTC (Universal Time, Coordinated) in the operating system, the BMC local time may not be mapped correctly. In order to filter the list, select the check boxes next to the desired event types and press Apply for the changes to take effect. Use the following information as reference.For further information on how to enable BitLocker drive encryption, please refer to the Microsoft Knowledge Base. Fujitsu service partners will find additional information (also available in Japanese) on the Fujitsu Extranet web pages. Upgrade and Maintenance Manual. Wait until the progress bar has reached at least one percent. By default, a fan test is automatically started every 24 hours. About power supply configurations The PRIMERGY TX120 S3 server is equipped with a standard PSU. CAUTION! The server supports a mains voltage in the range of 100 V - 240 V. You may only operate the server if its rated voltage range corresponds to the local mains voltage. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Be sure to back up your data before deleting a RAID array.Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Basic information The PRIMERGY TX120 S3 server features two system fan modules. Additional fans in PSU modules are integral parts of the power supply units and cannot be replaced separately. Figure 61: Removing the system fan module Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3.

    All other LEDs are only visible if the server cover has been opened. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Connecting the server to the mains The PRIMERGY TX120 S3 server is equipped with a standard power supply unit. CAUTION! The power supply automatically adjusts to any mains voltage in the range of 100 V - 240 V. The insulated connector cannot now be disconnected from the server accidentally. Upgrade and Maintenance Manual TX120 S3. On the operating system drive, BitLocker uses the compatible Trusted Platform Module (TPM) to detect if the computer's startup process has been modified from its original state. For further information on how to disable BitLocker drive encryption, please refer to the Microsoft Knowledge Base. Fujitsu service partners will find additional information (also available in Japanese) on the Fujitsu Extranet web pages. 5.1.2. The system starts the POST process.The card’s firmware is called by the system BIOS upon reboot and can be entered and configured. For details, refer to the dedicated documentation provided separately. Further information on suitable backup software solutions and related documentation is available to Fujitsu service partners from the Fujitsu Extranet pages. Re-enabling backup drives. When the value has reached ’0’, the system will shut down and power off. 5.2.6.1 Viewing the boot retry counter The current boot retry counter status is available in the BIOS:. As a result, the current operation mode (e.g. Mirrored Channel mode) may no longer be available due to a lack of identical memory module pairs. In this case, the operation mode will automatically revert to Independent Channel Mode. After the system board has been replaced, the system time is set automatically. By default, the RTC (Real Time Clock) time standard is set as the local time.

    Do not use sharp-edged tools like screw drivers as they may damage system board components when slipping. CAUTION! Ensure to insert the CMOS battery with the positive pole (label side) facing up as shown (see circle). Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. The UFM board contains customer information (e.g. IP address, license numbers). After replacing the UFM, hand the defective UFM board over to the customer.Upgrade and Maintenance Manual TX120 S3. Do not fasten the screw too firmly. Advise your contact persons that they must provide you with TPM backup copies.The effort when loosing the screw should be as low as possible. Otherwise the thin metal bar may break, rendering it impossible to loosen the screw. Advise your contact persons that they must provide you with TPM backup copies.Note on network settings recovery The following notes are required for TX120 S3p (PYT12Pxxx for Japanese market). After installing a new system board the TPM must be enabled. You may not clear the TPM data. If the contact persons DO NOT have a backup copy available, inform them that replacing the TPM board will cause to lose all data. Screw torque: 0.6 Nm (not applicable for the Japanese market) Tighten the screws in a cross diagonal pattern. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. CAUTION! Be careful not to touch or bend the pins on the processor socket. Save the socket cover for future use. The following notes are required for TX120 S3p (PYT12Pxxx for Japanese market). Configuration of network settings should be performed by the customer. Field Replaceable Units (FRU) Safety notes CAUTION.Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3.

    Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Figure 244: Connecting the power cable to the ODD Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. After that, the shoulder screw caps on the chassis floor will rest in the wide ends of the keyhole slots on the holder. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. The connector side with the three dots points towards you. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Component LEDs LEDs A, B and C are visible from the outside on the server rear. The serial connector COM1 can be used as default interface or to communicate with the iRMC S3. Indicator Status Description server has been highlighted using Identification ServerView Operations Manager or the blue on indicator ID button on the front panel for easy identification no critical event (CSS component) yellow on prefailure detected (CSS component) CSS indicator yellow CSS component failure. This button is used to reboot the system. It can be pressed using the end of a paper clip. Reset button CAUTION. Risk of data loss! The minimum startup configuration consists of the following components and cables: Component. Data Sheet. FUJITSU Server PRIMERGY TX120 S3p Tower Server. For small environments with high demandsAdditionallyTX servers can be rack-mounted to offer bestThis includesThey convincePRIMERGY TX120 S3p. Fujitsu Server PRIMERGY TX120 S3p: For smallIt is the perfectS3p is an excellent choice for smaller retailBesides sporting aData Sheet FUJITSU Server PRIMERGY TX120 S3p Tower Server. Main Features.

    The procedure for replacing the HDD fan module is the same as without the air duct because the air duct can remain in place. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. CAUTION! Keep the slot bracket for further use. Always replace slot brackets into unused PCI slot openings to comply with applicable EMC regulations and satisfy cooling requirements. Always replace slot brackets into unused PCI slot openings to comply with applicable EMC regulations and satisfy cooling requirements.Upgrade and Maintenance Manual TX120 S3. CAUTION! The connector side with the three dots (see close-up) shows upward. Upgrade and Maintenance Manual TX120 S3. Figure 90: Installed BBU in BBU holder Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. If this procedure still does not fix the BBU status, please contact your local Fujitsu customer service partner. Upgrade and Maintenance Manual TX120 S3. Batteries must be disposed of in accordance with local regulations concerning special waste.Upgrade and Maintenance Manual TX120 S3. After that, the shoulder screw caps on the chassis floor will rest in the wide ends of the keyhole slots on the holder. Batteries must be disposed of in accordance with local regulations concerning special waste.Batteries must be disposed of in accordance with local regulations concerning special waste.Batteries must be disposed of in accordance with local regulations concerning special waste.For further instructions regarding controller settings, please refer to the accompanying documentation. 9.4.1 Mounting expansion card slot brackets Customer Replaceable Units (CRU) Average task duration: 5 minutes This section provides general instructions on mounting slot brackets as well as. When replacing the slot bracket, ensure to use the original M3 x 5 mm screws. Standard M3 screws may damage onboard components.

    Upgrade and Maintenance Manual TX120 S3. Safety notes CAUTION. Do not install unsupported third party memory modules.Therefore both channels have to be populated with the same amount of memory. CAUTION! Ensure to maintain an operational configuration when removing memory modules.Safety notes CAUTION. Do not install unsupported processors.Upgrade and Maintenance Manual TX120 S3. This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and processor. Upgrade and Maintenance Manual TX120 S3. CAUTION! Be careful not to touch or bend the spring contacts on the processor socket. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. If the processor upgrade or replacement kit contains a new CPU heat sink, a thin layer of thermal compound has already been pre-applied to its lower surface. CAUTION! Do not mix different types of thermal paste. Upgrade and Maintenance Manual TX120 S3. Safety notes CAUTION.CAUTION! Save the ODD filler cover for future use. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. SATA cable Y3928-V205 Power cable Y4012-V501 connector P5 Upgrade and Maintenance Manual TX120 S3. SATA cable Y3928-V205 Power cable Y4012-V501 connector P5 Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. CAUTION! Save the backup drive filler cover for future use. Upgrade and Maintenance Manual TX120 S3. Upgrade and Maintenance Manual TX120 S3. Safety notes CAUTION.Upgrade and Maintenance Manual TX120 S3. Figure 179: Connecting the front LAN board to the system board Upgrade and Maintenance Manual TX120 S3. Please note that once removed, the front LAN cover plate cannot be refitted. Safety notes CAUTION.CAUTION!

    BenefitsData Sheet FUJITSU Server PRIMERGY TX120 S3p Tower Server. Technical details. PRIMERGY TX120 S3p. Base unit. Housing types. Storage drive architecture. Mainboard. Mainboard type. Chipset. Processor quantity and type. PRIMERGY TX120 S3p LFF. Ultra-compact form-factorMemory slots. Memory slot type. Memory capacity (min. - max.). Memory protection. Memory notesSingle channel (1 module) configuration possible. Memory optionsInterfaces. USB 2.0 ports. Graphics (15-pin). Serial 1 (9-pin). Management LAN (RJ45). Onboard or integrated Controller. RAID controller. SATA Controller. SATA controller type notes. LAN Controller. Remote management controller. Trusted Platform Module (TPM)Integrated Remote Management Controller (iRMC S3, 32 MB attached memory incl.IPMI 2.0 compatibleData Sheet FUJITSU Server PRIMERGY TX120 S3p Tower Server. Slots. PCI-Express 3.0 x16. PCI-Express 2.0 x1 (mech. x4). PCI-Express 2.0 x4 (mech. x8). PCI-slots. Slot Notes. Drive bays. Storage drive bays. Storage drive bay configuration. Accessible drive baysOptional hard disk bays. Not upgradeable in the field. None. Number of fans. Fan notesOperating panel. Operating buttons. Status LEDsCertified or supported operatingOperating system release linkSupport of other Linux derivatives on demand. Data Sheet FUJITSU Server PRIMERGY TX120 S3p Tower Server. Server Management. Standard. Option. Server Management notes. ServerView Remote Management (iRMC). ServerView Suite - MaintainAdvanced Video Redirection (AVR), video capturing and Virtual Media. ServerView Suite - Dynamize. Virtual-IO Manager (VIOM). Resource Orchestrator Virtual Edition (ROR VE). Resource Orchestrator Cloud Edition (ROR CE). ServerView Suite - Integrate. Regarding dependencies for ServerView Suite software products see dedicated product data sheets. Floor-stand (W x D x H). Dimension notes. Weight. Weight notesActual weight may vary depending on configuration. Environmental. Operating ambient temperature.

    Operating relative humidity. Operating environment. Operating environment link. Sound pressure (LpAm). Noise notesApparent power (max. configuration). Heat emission. Compliance. Global. Germany. Europe. South Korea. China. Compliance link. Compliance notesPower supply configuration. Standard power supply output. Rated voltage range. Rated frequency range. Rated current max. Rated current in basic configuration. Active power (min. configuration). Active power (max. configuration). Active power noteWEEE (Waste electrical and electronical equipment)FCC Class AThere is general compliance with the safety requirements of all European countries and North America. NationalThis is a class A product. In a domestic environment this product may cause radio interference in which case the userData Sheet FUJITSU Server PRIMERGY TX120 S3p Tower Server. Components. Backup Drives. Optical drives. RAID Controller. RAID level: 0, 1, 10, 5, 50, 6, 60, 512 MB Cache, Optional BBU for selected systems (based on LSI SAS2108). RAID level: 0, 1, 10, 5, 50, 6, 60, 1 GB, Optional FBU (based on LSI SAS2208). RAID level: 0, 1, 10, No BBU support. RAID level: 0, 1, 1E, No BBU support (based on LSI 1064e). Communication, Network. GraphicsData Sheet FUJITSU Server PRIMERGY TX120 S3p Tower ServerStandard WarrantyService level. Onsite ServiceSupport Pack Options. Globally available in major business areas:Recommended ServiceService LifecycleService WeblinkMore information. Fujitsu OPTIMIZATION Services. More information. Copyrights. In addition to Fujitsu PRIMERGY TX120 S3p. Fujitsu provides a range of platform solutions. They combine reliable Fujitsu products withLearn more about Fujitsu PRIMERGY TX120. S3p, please contact your Fujitsu salesAll rights reserved, including intellectualFor further information see Computing Products. Software.

    ContactFujitsu Green Policy Innovation is ourUsing our global know-how, we aim toPlease find further information at Build on industry standards, Fujitsu offers a fullDisclaimer. Technical data are subject to modification andAny liabilityDesignationsAll rights reserved, including intellectual property rights. Changes to technical data reserved. Delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded.For further information see. I played with a similar model to this a couple of years ago. See page 29 in the user's guide; All the options and procedures; Look for the version with xeon 1265l Almost 2 years now and not a single issue. Good box design and layout. If the price is right, I could recommend it based on past experience. It's easy! Sign in here. Any donation is appreciated. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. Your feedback helps us optimize our documentation to suit your individual needs. In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured.

    Please consult the sales staff of Fujitsu if intending to use this product for high safety use. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. These options and routines include: Additional security is provided by the lockable rack door. It contains all the information you need to put your PRIMERGY RX600 S6 into operation. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market). The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option. In case of RAID functionality the levels 0, 1, 1E, 5, 6, 10, 50 and 60 are supported. If one power supply unit is defective, the other(s) then guarantee(s) unimpaired operation.Further cooling for the installed processors is provided by hot-plug fans (optionally in a redundant configuration). If a temperature sensor fails or is removed, the fans affected run at maximum speed so as to provide the greatest possible protection for the hardware. The patented memory scrubbing function regularly starts up the EDC mechanism (Error Detection Code) and thus ensures continuous data integrity. If a memory module fails, the module with the defective memory is automatically deactivated and the replacement module is activated (provided it has been configured for appropriately in the BIOS). The deactivated memory module is no longer used and the faulty memory module can be replaced at the next opportunity. In order to be able to use the hot-spare memory function, all occupied DIMM slots must have an identical memory configuration.

    PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken. The ServerView Operations Manager supports the following functions: Further information on ServerView Local Service Display is provided in the associated documentation. The optional ServerView Remote Management remote testing and diagnostic system enables you to remotely maintain your server. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution. Links guide you to sections where you can find more detailed information on the individual steps: Here you can choose from two possibilities: If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team. A technical specialist is a person who is trained to install the server including hardware and software. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock. Material damage may be caused to the server if this requirement is not met. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage. When connecting the server, refer to the relevant instructions in this manual. If you install other expansions, they may damage the system or violate the safety regulations.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :